BLFMM - HENCO-SOLV, 104 (10-761)
- MSDS: BLFMM
- Manufacturer: E M CORP
- Product Name: HENCO-SOLV, 104 (10-761)
- National Stock Number: 6810-00N018154
Product Identification
Product ID:HENCO-SOLV, 104 (10-761)
MSDS Date:05/15/1991
FSC:6810
NIIN:00N018154
MSDS Number: BLFMM
Responsible Party
WEST LAFAYETTE, IN 47906
US
Emergency Phone: 317-497-6100;800-424-9300(CHEMTREC)
Info Phone: 501-862-5141
Preparer: CHEMICAL (SEE SUPP DATA)
Cage: EMCOR
Contractor
Telephone: (317) 497-6100
Cage: EMCOR
Ingredients
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 15-25%
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 20-30%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
2-ETHOXYETHYL ACETATE (CELLOSOLVE ACETATE) (EGEEA)
CAS: 111-15-9
RTECS: KK8225000
Fraction By Weight: 50-60%
OSHA PEL S,100 PPM
ACGIH TLV: S, 5 PPM; 9192
Hazards
LD50 LC50 Mixture:LD50:ORAL(RAT)2900 MG/KG FOR 111-15-9.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:XYLENE IS MOD SKIN IRRIT IN RABBITS &
SEV EYE IRRIT. TOLUENE IS SUGGESTED TO CAUSE LIVER ABNORMALITIES IN
HUMANS. TESTS IN LAB ANIMALS EXPOSED TO TOLUENE SHOW LIVER
ABNORMALITIES, KIDNEY, LUNG & SPLEE N DMG. CELLOSOLVE ACETATE IS
MILD EYE/SKIN IRRIT. ADVERSE REPRODUCTIVE EFFECTS & MALE
INFERTILITY HAVE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:BEEN OBSERVED IN LAB ANIMALS AT LEVELS
BELOW OSHA TWA. EYE:CAN CAUSE IRRIT,REDNESS, BLURRED VISION. SKIN:
PRLNG CNTCT CAN CAUSE IRRIT, DERM. INHAL:CAN CAUSE IRRIT, DIZZ,
NAUS, FATG, HDCH & UN CON/ASPHY. INGEST:CAN CAUSE GI IRRIT, NAUS,
VOMIT & DIARRHEA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN:WASH WITH SOAP & WATER. EYES:FLUSH WITH COPIOUS AMOUNTS
OF WATER FOR AT LEAST 15 MIN, GET MD. INHAL:REMOVE TO FRESH AIR. IF
BREATHING IS IMPAIRED, GET MD. INGEST:DO NOT INDUCE VOMIT, KEEP
WARM, G ET MD.
Fire Fighting
Flash Point Method:TCC
Flash Point:45.0F,7.2C
Extinguishing Media:CO2, FOAM, DRY CHEMICAL, HALON.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
EQUIP . DO NOT EXTINGUISH WITH WATER.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:CLEAN SPILL WITH ABSORBENT MATERIAL. ELIMINATE
IGNITION SOURCES. WEAR GLOVES, GOGGLES & GAS MASK IF TWA'S ARE
EXCEEDED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:PROTECT FROM PHYSICAL DAMAGE. STORE IN
COOL, DRY, VENTILATED AREA AWAY FROM ACIDS, ALKALIS & OPEN FLAMES.
Other Precautions:NONE.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC RESPIRATOR IF
TWA/ TLV LIMITS ARE EXCEEDED.
Ventilation:LOC EXHAUST-USE TO MAINT LEVELS BELOW TWA LIMITS.
MECHANICAL- USE NON-SPARKING EQUIPMENT.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PREPARER'S NAME:COMMUNICATIONS COORDINATOR.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:110F,43C
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAME.
Hazardous Decomposition Products:IRRITATING AND/OR TOXIC FUMES
INCLUDING CO & CO2 MAY BE RELEASED.
Disposal
Waste Disposal Methods:DISPOSE OF WASTE IN CHEMICAL LANDFILL I/A/W
FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.